Skip to main content
CVE Vulnerability Database
Vulnerability Database/CVE-2024-41985

CVE-2024-41985: Siemens Opcenter Quality Auth Bypass Flaw

CVE-2024-41985 is an authentication bypass flaw in Siemens Opcenter Quality that fails to expire idle sessions, allowing attackers unauthorized access. This article covers technical details, affected versions, and mitigations.

Updated:

CVE-2024-41985 Overview

CVE-2024-41985 affects SmartClient modules in Siemens Opcenter Quality, including Opcenter QL Home (SC), SOA Audit, and SOA Cockpit. The affected application does not expire the session without an explicit logout. An attacker on an adjacent network can reuse an idle session to gain unauthorized access to the application. The issue is tracked as CWE-613: Insufficient Session Expiration.

Siemens published advisory SSA-382999 describing the affected components and fixed release. The vulnerability requires user interaction and adjacent network access, which limits practical exploitation to environments where an attacker can reach an authenticated session context.

Critical Impact

An attacker with adjacent network access can reuse idle sessions of authenticated Opcenter Quality users, gaining unauthorized access to quality-management data and workflows.

Affected Products

  • Siemens Opcenter QL Home (SC) — all versions >= V13.2 and < V2506
  • Siemens SOA Audit — all versions >= V13.2 and < V2506
  • Siemens SOA Cockpit — all versions >= V13.2 and < V2506

Discovery Timeline

  • 2025-08-12 - CVE-2024-41985 published to NVD
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2024-41985

Vulnerability Analysis

The vulnerability is an insufficient session expiration flaw in the SmartClient modules of Siemens Opcenter Quality. Sessions established during authentication remain valid until an explicit logout occurs. Idle sessions are not terminated by a server-side timeout, so the associated session identifier remains usable long after the legitimate user has stopped interacting with the application.

An attacker who can access an unattended client, hijack a session token from an adjacent network segment, or reach the application through a shared workstation can resume the session without providing credentials. Because the flaw is a session management defect rather than a code execution primitive, its impact is scoped to unauthorized read and limited write actions within the application. The EPSS probability is low, consistent with the adjacent-network attack vector and required user interaction.

Root Cause

The SmartClient session handler does not enforce an idle timeout or inactivity-based invalidation. Session state is invalidated only when the user triggers the logout workflow. Any process or actor able to present the stored session identifier is treated as authenticated.

Attack Vector

Exploitation requires adjacent network access and user interaction. An attacker positioned on the same network segment as an authenticated Opcenter Quality client can obtain or reuse an idle session identifier, then issue requests as the original user. No credentials, tokens, or additional privileges are required beyond access to the session artifact.

No verified proof-of-concept code is publicly available for CVE-2024-41985. Refer to the Siemens Security Advisory SSA-382999 for vendor-provided technical detail.

Detection Methods for CVE-2024-41985

Indicators of Compromise

  • Application access from an Opcenter Quality user account after prolonged inactivity without a preceding authentication event.
  • Reuse of the same session identifier from a different source IP or workstation than the original login.
  • Concurrent active sessions for a single user account across the SmartClient modules.

Detection Strategies

  • Correlate authentication logs with application access logs to identify session activity that lacks a corresponding recent login event.
  • Baseline session lifetimes per user role and alert on sessions that exceed expected work-hour windows.
  • Monitor for session identifier reuse across differing client fingerprints, including User-Agent or source-address changes.

Monitoring Recommendations

  • Forward SmartClient, SOA Audit, and SOA Cockpit access logs to a centralized SIEM for retention and correlation.
  • Track logout events per session and flag sessions that terminate only through server restarts or manual cleanup.
  • Instrument network segments hosting Opcenter Quality clients for lateral connections to the SmartClient endpoints.

How to Mitigate CVE-2024-41985

Immediate Actions Required

  • Upgrade Opcenter QL Home (SC), SOA Audit, and SOA Cockpit to version V2506 or later as directed by Siemens advisory SSA-382999.
  • Instruct users to log out explicitly at the end of each session rather than closing the browser or client window.
  • Restrict network access to Opcenter Quality SmartClient endpoints to trusted management segments.

Patch Information

Siemens has released fixed versions in the V2506 branch for the affected SmartClient modules. Apply the update per the guidance in Siemens Security Advisory SSA-382999. No official patch identifier or hash is published beyond the version string in the advisory.

Workarounds

  • Enforce short operating-system or browser session lock timeouts on workstations accessing Opcenter Quality.
  • Terminate application sessions administratively at the end of each shift where feasible.
  • Segment the Opcenter Quality environment to prevent adjacent-network attackers from reaching authenticated client sessions.

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Default Legacy - Prefooter | Experience the World’s Most Advanced Cybersecurity Platform

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.