CVE-2024-41975 Overview
CVE-2024-41975 is a medium-severity information disclosure vulnerability affecting Programmable Logic Controllers (PLCs). An unauthenticated remote attacker can obtain limited information about the PLC network over the network. The PLCs' user management controls prevent the attacker from gaining actual access to the devices themselves.
The weakness is categorized under CWE-1188 (Initialization of a Resource with an Insecure Default). The flaw is reachable over the network without privileges or user interaction, but the impact is bounded to confidentiality of limited reconnaissance data.
Critical Impact
Unauthenticated remote attackers can enumerate limited PLC network information useful for reconnaissance, though direct device access remains blocked by user management controls.
Affected Products
- Programmable Logic Controllers (PLCs) referenced in VDE Security Advisory VDE-2025-013
- Refer to the vendor advisory for the authoritative list of affected PLC models and firmware versions
- Industrial control system (ICS) deployments exposing PLC network services
Discovery Timeline
- 2025-03-18 - CVE-2024-41975 published to NVD
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2024-41975
Vulnerability Analysis
The vulnerability exposes limited PLC network information to unauthenticated remote callers. An attacker on the same network path as the PLC can issue requests that reveal reconnaissance data about the control system environment. The disclosed information is limited in scope and does not provide a direct path to code execution or configuration tampering.
User management on the affected PLCs enforces authentication for operational access. This control prevents the attacker from leveraging the disclosed information to log in, modify logic, or disrupt process control. The confidentiality impact is therefore partial rather than complete.
In industrial environments, even limited network reconnaissance aids targeted follow-on attacks. Attackers combine such data with other weaknesses to map asset inventories, identify firmware versions, and plan lateral movement toward engineering workstations.
Root Cause
The root cause is tied to CWE-1188, which describes insecure default initialization of a resource. The PLC exposes network-accessible endpoints that return information without first requiring authentication. The product's security model places the confidentiality control at the user-management layer, leaving the reconnaissance surface open.
Attack Vector
The attack vector is network based and requires no authentication or user interaction. An attacker with reachability to the PLC management or process network sends crafted requests to the exposed service. The response reveals limited information about the PLC network topology or device metadata. See VDE Security Advisory VDE-2025-013 for protocol-specific details.
Detection Methods for CVE-2024-41975
Indicators of Compromise
- Unauthenticated network probes targeting PLC management ports from unexpected sources
- Spikes in low-volume connection attempts from non-engineering hosts to control system subnets
- Session establishment to PLC services from IP addresses outside the approved engineering workstation range
Detection Strategies
- Deploy network intrusion detection signatures tuned to the PLC vendor's management protocol traffic patterns
- Correlate flows between IT and OT segments to identify unauthorized access to control system VLANs
- Baseline normal PLC query behavior from engineering stations and alert on deviations in source, frequency, or payload
Monitoring Recommendations
- Enable OT-aware network monitoring at the Purdue Level 2/3 boundary to capture all PLC-directed traffic
- Forward switch SPAN or TAP data covering control system subnets to a centralized analytics platform
- Review authentication and session logs on PLCs daily for anomalous unauthenticated requests
How to Mitigate CVE-2024-41975
Immediate Actions Required
- Review VDE Security Advisory VDE-2025-013 to confirm which PLC models and firmware versions are affected
- Restrict network reachability to PLCs using firewall rules that allow only approved engineering workstations
- Audit existing exposure by scanning OT segments for PLC services reachable from IT networks or the internet
Patch Information
Consult VDE Security Advisory VDE-2025-013 for vendor-supplied firmware updates and remediation guidance. Apply firmware updates during planned maintenance windows and validate the change in a test environment before production rollout.
Workarounds
- Segment PLCs behind dedicated OT firewalls and deny all inbound traffic from IT or external networks
- Place PLCs on isolated VLANs reachable only through jump hosts with strong authentication and session logging
- Disable or filter any PLC management protocol not required for operations, following the vendor's hardening guide