Skip to main content
Vulnerability Database/CVE-2024-30601

CVE-2024-30601: Tenda FH1203 Buffer Overflow Vulnerability

CVE-2024-30601 is a stack overflow vulnerability in Tenda FH1203 Firmware affecting the saveParentControlInfo function. Attackers can exploit this flaw to compromise device security. This article covers technical details, affected versions, and mitigation strategies.

Published:

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

CVE-2024-30601 Overview

CVE-2024-30601 is a stack overflow vulnerability affecting the Tenda FH1203 router running firmware version 2.0.1.6. The flaw resides in the saveParentControlInfo function, where the time parameter is processed without proper bounds checking. An authenticated attacker on the adjacent network can send a crafted request that overflows the stack buffer, leading to memory corruption and potential code execution on the device.

Critical Impact

Successful exploitation can compromise confidentiality, integrity, and availability of the affected router, potentially giving attackers persistent control over network traffic traversing the device.

Affected Products

  • Tenda FH1203 router (hardware)
  • Tenda FH1203 firmware version 2.0.1.6
  • Deployments exposing the web management interface to adjacent networks

Discovery Timeline

  • 2024-03-28 - CVE-2024-30601 published to the National Vulnerability Database (NVD)
  • 2026-06-17 - Last updated in NVD database

Technical Details for CVE-2024-30601

Vulnerability Analysis

The vulnerability is a classic stack-based buffer overflow categorized as [CWE-121]. The saveParentControlInfo function in the FH1203 firmware handles parental control configuration submitted through the device's web interface. The time parameter in the request body is copied into a fixed-size stack buffer without validating the input length.

When an attacker supplies a time value exceeding the buffer boundary, adjacent stack memory is overwritten. This can corrupt saved registers, including the return address, which can redirect execution flow. On embedded MIPS or ARM targets like the FH1203, this typically enables arbitrary code execution within the context of the web management daemon running as root.

Root Cause

The root cause is improper input validation on a user-controlled parameter before it reaches an unsafe memory operation. The firmware does not enforce a maximum length on the time field, nor does it use bounded string functions when copying the parameter into the stack buffer.

Attack Vector

Exploitation requires network adjacency and valid low-privilege credentials to the management interface. An attacker on the same LAN or Wi-Fi segment submits a crafted HTTP request to the parental control endpoint containing an oversized time parameter. No user interaction is required beyond authentication.

Technical details and reproduction steps are documented in the public GitHub IoT Vulnerability Report. No code examples are reproduced here because no verified exploit artifacts are available in the enriched dataset.

Detection Methods for CVE-2024-30601

Indicators of Compromise

  • HTTP POST requests to the parental control endpoint containing abnormally long time parameter values
  • Unexpected restarts or crashes of the Tenda web management daemon (httpd)
  • Unauthorized changes to parental control configuration not initiated by administrators
  • New administrative sessions originating from adjacent network segments

Detection Strategies

  • Inspect HTTP traffic to the router management interface for oversized parameter values in saveParentControlInfo requests
  • Correlate authentication logs with configuration change events to identify low-privilege accounts attempting administrative actions
  • Monitor for repeated connection attempts to port 80 or 443 on router management addresses from unexpected hosts

Monitoring Recommendations

  • Deploy network monitoring to log all management-plane traffic to Tenda devices
  • Alert on sustained bursts of HTTP requests targeting administrative endpoints from adjacent LAN hosts
  • Collect router syslog output centrally and alert on daemon crashes or restart loops that may indicate exploitation attempts

How to Mitigate CVE-2024-30601

Immediate Actions Required

  • Restrict access to the FH1203 web management interface to a dedicated management VLAN
  • Change default and weak administrative credentials to reduce the pool of adjacent attackers who meet the authentication requirement
  • Disable remote management interfaces that are not strictly required for operations
  • Segment IoT and router management networks from general user and guest Wi-Fi segments

Patch Information

No vendor patch or security advisory is referenced in the enriched CVE data. Administrators should monitor the Tenda support site for firmware updates addressing CVE-2024-30601 and consider replacing end-of-life hardware if no fix is published.

Workarounds

  • Place the FH1203 behind a firewall that enforces strict ACLs on management ports
  • Disable the parental control feature if it is not required in the deployment
  • Require VPN access for any administrative session to the device
  • Rotate administrator credentials and enforce strong passwords on all accounts
bash
# Example firewall rule limiting router management access to a trusted host
iptables -A INPUT -p tcp --dport 80 -s 192.0.2.10 -j ACCEPT
iptables -A INPUT -p tcp --dport 80 -j DROP
iptables -A INPUT -p tcp --dport 443 -s 192.0.2.10 -j ACCEPT
iptables -A INPUT -p tcp --dport 443 -j DROP

Disclaimer: This content was generated using AI. While we strive for accuracy, please verify critical information with official sources.

Sources: National Vulnerability Database, CISA KEV, Exploit-DB

Experience the Most Advanced Cybersecurity Platform

See how the world’s most intelligent, autonomous cybersecurity platform can protect your organization today and into the future.