CVE-2024-0865 Overview
CVE-2024-0865 is a hard-coded credentials vulnerability [CWE-798] in Schneider Electric EcoStruxure IT Gateway. A non-administrative user who is already logged in to an affected host can leverage embedded credentials to escalate privileges locally. Schneider Electric disclosed the issue in security notice SEVD-2024-044-03 and published it to the NVD on June 12, 2024.
The flaw affects deployments of EcoStruxure IT Gateway used to monitor distributed data center and industrial infrastructure. Successful exploitation grants an attacker elevated access on the Gateway host, exposing sensitive telemetry and management functions.
Critical Impact
An authenticated local user can abuse hard-coded credentials to gain full control of the EcoStruxure IT Gateway host, breaking the confidentiality, integrity, and availability of monitored assets.
Affected Products
- Schneider Electric EcoStruxure IT Gateway (see SEVD-2024-044-03 for version ranges)
- Deployments integrating EcoStruxure IT Gateway with on-premises monitoring consoles
- Hosts where the Gateway service runs with elevated privileges
Discovery Timeline
- 2024-06-12 - CVE-2024-0865 published to NVD alongside Schneider Electric advisory SEVD-2024-044-03
- 2026-06-17 - Last updated in NVD database
Technical Details for CVE-2024-0865
Vulnerability Analysis
The vulnerability stems from credentials embedded directly in the EcoStruxure IT Gateway product. Any actor with knowledge of these static credentials can authenticate to a privileged interface exposed on the local host. Because the credentials are shipped with the software, they are identical across installations and cannot be rotated by the operator.
Exploitation requires only local access and low-privileged authentication to the host. No user interaction is needed, and the attack complexity is minimal. The scope remains unchanged, but the attacker gains the full set of permissions associated with the Gateway service account, which typically runs with high privileges.
Schneider Electric classifies the issue under CWE-798: Use of Hard-coded Credentials. The EPSS score of 0.238% reflects a currently low observed exploitation probability, but hard-coded credentials remain highly reliable once discovered through reverse engineering.
Root Cause
The Gateway binaries or configuration files contain static authentication material. Developers embedded the credentials to support internal service communication or recovery workflows. Because the secrets are not derived from installation-specific entropy, every deployment shares the same trust anchor.
Attack Vector
An attacker first obtains an interactive or service session on the host running EcoStruxure IT Gateway as a non-administrative user. The attacker then authenticates to a Gateway component using the hard-coded credentials recovered from the installed files. Successful authentication yields privileged operations on the Gateway, which can be chained to execute commands or alter configuration under the Gateway service identity.
See the Schneider Electric Security Notice SEVD-2024-044-03 for the vendor's technical description.
Detection Methods for CVE-2024-0865
Indicators of Compromise
- Local logons by low-privileged accounts followed by Gateway service actions normally reserved for administrators.
- Unexpected use of the Gateway's local authentication endpoints from interactive sessions.
- New administrative objects, scheduled tasks, or services created by the Gateway service account.
Detection Strategies
- Baseline the Gateway service account's normal activity, then alert on deviations such as spawning command interpreters or writing to system directories.
- Correlate local interactive logons with subsequent privileged API calls to the Gateway, which should be rare on production hosts.
- Hunt for processes reading Gateway binaries or configuration files from non-administrative user contexts.
Monitoring Recommendations
- Forward Windows Security, Sysmon, and Gateway application logs to a central SIEM for correlation.
- Monitor file integrity on EcoStruxure IT Gateway installation directories to detect credential extraction attempts.
- Track network traffic between Gateway components for authentication events originating from unexpected local processes.
How to Mitigate CVE-2024-0865
Immediate Actions Required
- Apply the fixed EcoStruxure IT Gateway release identified in SEVD-2024-044-03 as soon as change windows permit.
- Restrict interactive and remote logon rights on Gateway hosts to a minimal set of administrators.
- Inventory all EcoStruxure IT Gateway deployments and confirm patch status for each instance.
Patch Information
Schneider Electric published remediation guidance in Schneider Electric Security Notice SEVD-2024-044-03. Operators should upgrade to the vendor-supplied fixed version and validate the installation against the advisory's integrity checks.
Workarounds
- Isolate Gateway hosts on a dedicated management VLAN and block non-essential local access.
- Remove or disable unused local accounts on Gateway hosts to reduce the pool of actors able to reach the vulnerable interface.
- Enforce application allow-listing so only approved binaries can execute within the Gateway host's user context.